Applications
Domestic and Industrial Natural Gas Installations, LPG Installations, Conduction of all kinds of Flammable and Explosive Gasses & Conduction of Petroleum and Petroleum Derivatives.
Production Range | |
External Diameter: | 21.3 mm - 339.7 mm |
External Coating Length: | 6m – 8.5m |
Internal Coating Length: | 6m – 14m |
Production Standards |
|
Surface Preparation: | ISO 8501 - 1, ISO 8502 - 3, ISO 8503 - 1 |
External Coating | |
3 Layer Polyethylene Coating: | DIN 30670, TS EN 10288, UNI 9099, NFA 49710 |
Polypropylene Coating: | DIN 30678, NFA 49711 |
Internal Coating | AWWA C 210 |
Polypropylene Coating: | AWWA C 222 |
Coating Quality Control | |
Surface Control After Blasting Tests: | Surface Quality Control Test Dust Content Test Roughness Test Measuring Weather Conditions Test |
3 Layer Polyethylene Coating Tests: | Thickness Measuring Test Holiday Test Indentation Hardness Test Percentage Elongation Test Bond Strength Test Impact Strength Test Electrical Resistivity Test Cathodic Disbonding Test |
Epoxy Coating Tests: | Thickness Measuring Test Holiday Test Methyl Ethyl Ketone Rasping Test X - Cut Bond Strength Test Chemical Immersion Test |
Polyurethane Coating Tests: | Thickness Measuring Test Holiday Test Flexibility Test V - Cut Bond Strength Test Chemical Strength Test Cathodic Disbonding Test |
Protective Coating Range, Click Below