Water & Gas Pipes, Galvanised Pipes, Threaded & Coupled Pipes
Applications
Used for conduction of non-flammable gasses and fluids and applications such as installations and green housing.
Production Range
Metric | Imperial | |
External Diameter: | 17.2 - 339.7mm | 3/8" - 13 3/8" |
Wall Thickness: | 1 - 13 mm | 0.039" - 0.511" |
Plain End, Bevelled Length: | 4 - 14.6m | 13' - 46' feet |
Threaded and Coupled Length: | 5 - 8.5m |
- |
**Length Varies According To Dimensions
Production Standards
EN 10255 CE MARKED, EN 10224, EN 10217-1, EN 10217-2, , DIN 1626, DIN 2440, DIN 2441 , BS 1387, NFA 49-145,ISO 65, UNI 8863 , SI 103, SI 530, SI 4314, ASTM A 795, ASTM A 53
Material Quality / Steel Grade
DIN 17100 / DIN 1626: | St 33, St 37 |
EN 10025: | S 195, S 235 JR, S 235 J0, S 235 J2 |
EN 10217-1: | P 195 TR1/TR2, P 235 TR1/TR2, P 265 TR1/TR2 |
EN 10217-2: | P 195 GH / P235 GH / P 265 GH / 16 Mo 3 |
EN 10255: | S 195 T |
SI 103: | S 332, S 414 |
BS 4360: | 40 A, 43 A |
SI 530: | 530 A, 530 B, 530/42 |
EN 10224: | L235,L275,L355 |
Galvanising Standards
EN 10240, DIN 2444, ASTM A 90, ASTM A 53, SI 103, SI 918, BS 729
Threading Standards
TS 301, DIN 2999, ISO 7-1, BS 21, ANSI B1 20.1, SI 50.3
Finishing Operations
Square Cut, Bevelled End, Threaded and Coupled
Surface Protection
Protective Oil, Hot Dip Galvanised, Primer Coated
Mill Test Certificates
In accordance to EN 10204 2.1, 2.2, 3.1, 3.2
Production Program
Water and Gas Pipes, Galvanized Pipes, Threaded & Coupled Pipes
Quality Control
Leak Tightness Testing: | Hydrostatic test |
Non-Destructive Test: | Eddy Current test Ultrasonic Test of weld seam (60.3 – 339.7 mm) (2 3/8" – 13 3/8") |
Destructive Tests: | Flattening Test Bending Test Expanding Test Tensile Test Charpy V Notch Impact test |
Chemical Analysis: | Spectral Analysis |
Other: | Visual and Dimensional Check |
Water and Gas Pipes Range, Click Below